{"product_id":"coleman-mach-47201-079-mach-8-plus-cub-rooftop-ac","title":"MACH 8 PLUS CUB  9 200 BTU A\/C  BLA","description":"\u003cdiv style=\"max-width:100%;box-sizing:border-box;color:#374151;font-size:16px;line-height:1.7;overflow-wrap:break-word;\"\u003e\n\u003cp style=\"margin:0 0 8px;color:#b52828;font-size:12px;font-weight:700;letter-spacing:1.3px;text-transform:uppercase;\"\u003eColeman-Mach · RV Rooftop Air Conditioners\u003c\/p\u003e\n\u003ch2 style=\"margin:0 0 16px;color:#1f2937;font-size:22px;line-height:1.35;\"\u003eColeman-Mach 47201-079 Mach 8 Plus Cub Rooftop A\/C\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eColeman-Mach 47201-079 is the textured-black Mach 8 Plus Cub rooftop air conditioner with a nominal 9,200 BTU cooling rating and an 8-1\/4-inch profile. It is the upper cooling unit for a properly matched RV installation, not a complete ceiling-and-controls package.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eIts moulded fiberglass basepan supports the low-profile design. Use it with compatible ducted or non-ducted components selected for the actual RV; the interior ceiling assembly must be ordered separately.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:24px;max-width:100%;box-sizing:border-box;\"\u003e\n\u003cdiv style=\"flex:2 1 400px;min-width:0;max-width:100%;box-sizing:border-box;\"\u003e\n\u003ch3 style=\"margin:22px 0 10px;color:#1f2937;font-size:19px;line-height:1.4;\"\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul style=\"padding-left:22px;list-style:disc;margin:0 0 18px;\"\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003eNominal 9,200 BTU cooling capacity in the compact Mach 8 Plus Cub configuration.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003e8-1\/4-inch rooftop height reduces the above-roof profile compared with taller unit designs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003eOne-piece fiberglass basepan combines rigidity with reduced basepan weight.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003eTextured-black shroud matches this exact -079 configuration.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003eSupports a matched ducted or non-ducted installation.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003eCooling-only rooftop unit: no heat pump or condensate pump is included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin:22px 0 10px;color:#1f2937;font-size:19px;line-height:1.4;\"\u003eCompatibility \u0026amp; Applications\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eIntended for a suitable RV roof installation using a nominal 14 x 14-inch vent opening. The roof structure must support both the upper unit and the separately selected ceiling assembly, and the installer must check the permitted opening, roof thickness, level and clearance requirements in the guide.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eVerify compatibility with the actual ceiling assembly, control board, thermostat and ducting before replacing an existing unit. Matching the roof opening alone is not enough.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eThe electrical supply is a 115VAC-rated, 60Hz, single-phase RV circuit, commonly described as a nominal 120V system. Have the installer use the actual unit nameplate for circuit protection, wiring and supply requirements; this is not a 12V rooftop A\/C.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003caside style=\"flex:1 1 300px;min-width:0;max-width:100%;box-sizing:border-box;\"\u003e\u003cdiv style=\"padding:18px;background:#f5f6f8;border-radius:8px;box-sizing:border-box;max-width:100%;\"\u003e\n\u003ch3 style=\"margin:22px 0 10px;color:#1f2937;font-size:19px;line-height:1.4;\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;width:100%;font-size:14px;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eManufacturer part number\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003e47201-079\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eMach 8 Plus Cub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eCooling capacity\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003e9,200 BTU\/h nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eFunction\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eA\/C only; no heat pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eRoof opening\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eNominal 14 x 14 inches; verify installation-guide limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003e8-1\/4 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eColour\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eTextured black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eBasepan\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eOne-piece moulded fiberglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eElectrical rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003e115VAC, 60Hz, 1 phase; nominal 120V system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eExisting compressor-current description\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eApproximately 9A; not total\/start-up circuit sizing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eExact-part reseller full-load reference\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003e9.3A low fan \/ 9.9A high fan; verify actual nameplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eAir delivery reference\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003e300 CFM on high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eListed unit weight\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003e87 lb; allow for installation\/support requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eCondensate pump \/ remote\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eNot supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eCeiling assembly\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eRequired, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eInstallation planning estimate\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eApproximately 1.5 hours in existing data; actual installation varies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eLimited 2 years, subject to applicable manufacturer terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:22px 0 10px;color:#1f2937;font-size:19px;line-height:1.4;\"\u003eWhat's Included\u003c\/h3\u003e\n\u003cul style=\"padding-left:22px;list-style:disc;margin:0 0 18px;\"\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003eOne textured-black 47201-079 rooftop cooling unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003eCeiling assembly\/air-distribution box, thermostat, control board and optional heat-strip accessory are separate selections. This listing does not include a heat pump, condensate pump or remote control.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003eThe roof support, electrical circuit and any required adaptation to the existing RV installation must be assessed separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin:22px 0 10px;color:#1f2937;font-size:19px;line-height:1.4;\"\u003eInstallation, Use \u0026amp; Care\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eInstallation and electrical service require a qualified RV A\/C technician. Disconnect power and follow the manufacturer’s 47000-series guide together with all instructions supplied with the actual upper unit and chosen ceiling assembly.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eInspect the structural framing, roof opening, gasket and interior clearance before lifting the unit into position. The guide says not to lift it by the plastic shroud.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eKeep the correct relationship between the rooftop unit and interior assembly, and compress the gasket as illustrated. Use the unit nameplate and supplied documentation for electrical and fastener requirements.\u003c\/p\u003e\n\u003cul style=\"padding-left:22px;list-style:disc;margin:0 0 18px;\"\u003e\u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"https:\/\/www.rvproductsshop.com\/media\/documentation\/installation_instructions\/47000%20Series%20AC.pdf\" target=\"_blank\" rel=\"noopener\"\u003eColeman-Mach 47000-series installation, operation and maintenance guide — manufacturer 1980-002 Rev 2\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eClean or replace the ceiling assembly’s approved filters regularly; the guide recommends at least every two weeks during use. Do not operate for extended periods without the filter.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eInspect the shroud and mounting condition periodically. A technician should investigate repeated circuit trips, abnormal starting or loss of cooling.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eAvoid rapid compressor cycling. The guide calls for a two-to-three-minute pause after switching off before restarting. Cooling effectiveness also depends on the RV’s insulation, sun exposure, windows and heat load.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/aside\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"margin:22px 0 10px;color:#1f2937;font-size:19px;line-height:1.4;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdiv style=\"background:#fff;margin-bottom:18px;border:1px solid #d9dee5;border-radius:8px;overflow:hidden;\"\u003e\n\u003ch3 style=\"margin:0;padding:14px 16px;background:#f1f3f5;color:#1f2937;font-size:17px;font-weight:700;line-height:1.5;\"\u003e\u003cstrong\u003eQ: Is this a complete rooftop-and-ceiling package?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"margin:0;padding:14px 16px;color:#374151;font-size:15px;line-height:1.7;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. It is the upper cooling unit. The compatible ceiling assembly and controls must be selected separately.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;margin-bottom:18px;border:1px solid #d9dee5;border-radius:8px;overflow:hidden;\"\u003e\n\u003ch3 style=\"margin:0;padding:14px 16px;background:#f1f3f5;color:#1f2937;font-size:17px;font-weight:700;line-height:1.5;\"\u003e\u003cstrong\u003eQ: Is it rated at 9,000 or 9,200 BTU?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"margin:0;padding:14px 16px;color:#374151;font-size:15px;line-height:1.7;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The exact specifications and existing product data identify 9,200 BTU nominal cooling. Some reseller headings round that description to 9,000 BTU.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;margin-bottom:18px;border:1px solid #d9dee5;border-radius:8px;overflow:hidden;\"\u003e\n\u003ch3 style=\"margin:0;padding:14px 16px;background:#f1f3f5;color:#1f2937;font-size:17px;font-weight:700;line-height:1.5;\"\u003e\u003cstrong\u003eQ: Can it be installed on ducted and non-ducted RVs?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"margin:0;padding:14px 16px;color:#374151;font-size:15px;line-height:1.7;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, with the correctly matched interior assembly, controls and duct arrangement. Confirm those components before ordering a replacement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;margin-bottom:18px;border:1px solid #d9dee5;border-radius:8px;overflow:hidden;\"\u003e\n\u003ch3 style=\"margin:0;padding:14px 16px;background:#f1f3f5;color:#1f2937;font-size:17px;font-weight:700;line-height:1.5;\"\u003e\u003cstrong\u003eQ: Does it heat as supplied?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"margin:0;padding:14px 16px;color:#374151;font-size:15px;line-height:1.7;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e This is not a heat pump. A compatible optional electric heat accessory is a separate selection, not included cooling capacity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;margin-bottom:18px;border:1px solid #d9dee5;border-radius:8px;overflow:hidden;\"\u003e\n\u003ch3 style=\"margin:0;padding:14px 16px;background:#f1f3f5;color:#1f2937;font-size:17px;font-weight:700;line-height:1.5;\"\u003e\u003cstrong\u003eQ: Will any 14-inch roof opening be sufficient?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"margin:0;padding:14px 16px;color:#374151;font-size:15px;line-height:1.7;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The installer must also check structural support, opening limits, roof thickness, level, clearances and electrical supply.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;margin-bottom:18px;border:1px solid #d9dee5;border-radius:8px;overflow:hidden;\"\u003e\n\u003ch3 style=\"margin:0;padding:14px 16px;background:#f1f3f5;color:#1f2937;font-size:17px;font-weight:700;line-height:1.5;\"\u003e\u003cstrong\u003eQ: Can I use the nine-amp figure to size the power circuit?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"margin:0;padding:14px 16px;color:#374151;font-size:15px;line-height:1.7;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. That approximate compressor figure is not a start-up or total-system circuit specification. Use the actual nameplate and manufacturer wiring\/protection requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;margin-bottom:18px;border:1px solid #d9dee5;border-radius:8px;overflow:hidden;\"\u003e\n\u003ch3 style=\"margin:0;padding:14px 16px;background:#f1f3f5;color:#1f2937;font-size:17px;font-weight:700;line-height:1.5;\"\u003e\u003cstrong\u003eQ: Is the newer 37201-079 the same exact model?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"margin:0;padding:14px 16px;color:#374151;font-size:15px;line-height:1.7;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. It is a different model number listed as a replacement by the reseller. This page describes 47201-079; do not transfer the newer model’s refrigerant or electrical data to it.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;margin-bottom:18px;border:1px solid #d9dee5;border-radius:8px;overflow:hidden;\"\u003e\n\u003ch3 style=\"margin:0;padding:14px 16px;background:#f1f3f5;color:#1f2937;font-size:17px;font-weight:700;line-height:1.5;\"\u003e\u003cstrong\u003eQ: Why are clean filters important?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"margin:0;padding:14px 16px;color:#374151;font-size:15px;line-height:1.7;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Restricted airflow reduces cooling and can contribute to evaporator icing. Use the filter type recommended for the actual ceiling assembly and clean it regularly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdetails open=\"open\" style=\"margin-top:24px;\"\u003e\u003csummary style=\"font-weight:700;color:#b52828;cursor:pointer;\"\u003eMore product details \u0026amp; helpful resources\u003c\/summary\u003e\u003cdiv style=\"padding-top:16px;\"\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eUse the \u003ca href=\"https:\/\/www.rvproductsshop.com\/coleman-mach-8-47201-079-ultra-low-profile-9-000-btu-120v-air-conditioner-textured-black.html\" target=\"_blank\" rel=\"noopener\"\u003eauthorized reseller’s exact 47201-079 specification record\u003c\/a\u003e alongside the manufacturer-authored guide linked above. The installer should use the actual model\/serial label and unit documents when choosing replacement controls or service parts.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e The supplied manufacturer guide identifies a limited two-year warranty. Follow the statement supplied with the actual unit for eligibility and exclusions. An optional extended-parts contract discussed in the older guide is separate; its old price and availability are not an offer in this listing.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eSelect capacity for the RV’s actual heat gain, rather than assuming one rooftop unit cools every vehicle size. Shading, insulation and keeping doors\/windows closed affect the cooling load.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"COLEMAN RVP","offers":[{"title":"Default Title","offer_id":47651402809629,"sku":"BXPQ_47201-079","price":1189.35,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0689\/2771\/7661\/files\/ImageServer_64a43c5a-28c1-4fa4-9225-40931de71ea3.png?v=1757539559","url":"https:\/\/www.mytruckpoint.ca\/products\/coleman-mach-47201-079-mach-8-plus-cub-rooftop-ac","provider":"TruckPoint","version":"1.0","type":"link"}