{"product_id":"coleman-mach-48209-0660-mach-15-powersaver-air-conditioner","title":"Coleman Mach 48209-0660 MACH 15  15 000 BTU POWER SAVER A\/C","description":"\u003cdiv style=\"max-width:100%;box-sizing:border-box;color:#374151;font-size:16px;line-height:1.7;overflow-wrap:break-word;\"\u003e\n\u003cp style=\"margin:0 0 8px;color:#b52828;font-size:12px;font-weight:700;letter-spacing:1.3px;text-transform:uppercase;\"\u003eColeman-Mach · RV Rooftop Air Conditioners\u003c\/p\u003e\n\u003ch2 style=\"margin:0 0 16px;color:#1f2937;font-size:22px;line-height:1.35;\"\u003e48209-0660 Mach 15 PowerSaver 15,000 BTU A\/C\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eColeman-Mach 48209-0660 is the textured-white Mach 15 PowerSaver rooftop cooling unit for a compatible RV installation. Its nominal 15,000 BTU\/h capacity and 320 CFM listed airflow provide the buying specifications for this legacy part number; the interior ceiling assembly is separate.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eThis is a refrigerant air conditioner without a heat pump or condensate pump. Match the full model number and the RV’s ceiling\/control arrangement rather than treating every Mach 15 version as interchangeable.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:24px;max-width:100%;box-sizing:border-box;\"\u003e\n\u003cdiv style=\"flex:2 1 400px;min-width:0;max-width:100%;box-sizing:border-box;\"\u003e\n\u003ch3 style=\"margin:22px 0 10px;color:#1f2937;font-size:19px;line-height:1.4;\"\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul style=\"padding-left:22px;list-style:disc;margin:0 0 18px;\"\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003ePowerSaver configuration designed to reduce cooling power demand within a properly sized RV electrical system.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003eMedium-profile textured-white rooftop shroud.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003eListed 8.9 A compressor draw; this is not the total unit current or a circuit-size recommendation.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003eSeparate rooftop and interior assemblies allow the installation to be matched to the RV’s airflow and control system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin:22px 0 10px;color:#1f2937;font-size:19px;line-height:1.4;\"\u003eCompatibility \u0026amp; Applications\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eNominal 14 × 14-inch roof-opening application with suitable framing, roof load support and mounting clearance.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eExact 48209-0660 is identified as the Ducted Quiet configuration in the available exact-part listing. Confirm the ceiling\/control match before any non-ducted conversion.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eVerify the rooftop unit and ceiling assembly model\/serial numbers separately, including thermostat and control-box compatibility.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eA replacement or superseding MPN must be checked as its own configuration; specifications from a newer refrigerant revision are not substituted here.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003caside style=\"flex:1 1 300px;min-width:0;max-width:100%;box-sizing:border-box;\"\u003e\u003cdiv style=\"padding:18px;background:#f5f6f8;border-radius:8px;box-sizing:border-box;max-width:100%;\"\u003e\n\u003ch3 style=\"margin:22px 0 10px;color:#1f2937;font-size:19px;line-height:1.4;\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;width:100%;font-size:14px;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eManufacturer part number\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003e48209-0660\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eSeries \/ function\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eMach 15 PowerSaver \/ cooling A\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eNominal cooling capacity\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003e15,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eElectrical supply\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eNominal 120 V AC RV supply; 115 VAC rated equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eListed compressor draw\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003e8.9 A; excludes fan and other loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eAirflow\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003e320 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eListed rooftop size\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003e13.8 H × 26.1 W × 38 L inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eListed rooftop weight\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003e83.5 lb; interior assembly additional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eFinish\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eTextured white\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eHeat pump \/ condensate pump \/ remote\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border-bottom:1px solid #d9dee5;vertical-align:top;\"\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:22px 0 10px;color:#1f2937;font-size:19px;line-height:1.4;\"\u003eWhat's Included\u003c\/h3\u003e\n\u003cul style=\"padding-left:22px;list-style:disc;margin:0 0 18px;\"\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003eOne 48209-0660 rooftop air conditioner.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003eCeiling assembly, compatible thermostat\/control equipment and optional electric heating equipment are ordered separately.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003eThis listing does not include a complete rooftop-plus-ceiling package.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin:22px 0 10px;color:#1f2937;font-size:19px;line-height:1.4;\"\u003eInstallation, Use \u0026amp; Care\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eHave a qualified RV installer verify the roof structure, opening, gasket, ceiling\/control system and electrical supply.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eDisconnect all power before installation or service. Use the actual unit nameplate to determine complete load, conductor sizing and protective-device requirements.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eThe original 1½-hour estimate assumes a suitable existing installation; roof work, wiring and new controls can require more time.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eThe available legacy manual download could not be retrieved in this run. Use the documentation supplied with the exact unit and the manufacturer’s legacy document library.\u003c\/p\u003e\n\u003cul style=\"padding-left:22px;list-style:disc;margin:0 0 18px;\"\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"https:\/\/www.rvproductsshop.com\/media\/documentation\/installation_instructions\/48000%20Series%20AC.pdf\" target=\"_blank\" rel=\"noopener\"\u003eColeman-Mach 48000-series installation, operation and maintenance PDF — download access unconfirmed\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"https:\/\/coleman-mach.com\/document-library\/\" target=\"_blank\" rel=\"noopener\"\u003eColeman-Mach legacy document library — match complete model number\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eMaintain the correct return-air filters and keep the air paths clear. Refer to the exact ceiling assembly’s instructions for removal and cleaning.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eUse suitable mild cleaning products on the exterior and have electrical or refrigeration faults handled by qualified service personnel.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eDo not treat a compressor-only amp figure as evidence that a small generator can start and run the complete installation.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/aside\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"margin:22px 0 10px;color:#1f2937;font-size:19px;line-height:1.4;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdiv style=\"background:#fff;margin-bottom:18px;border:1px solid #d9dee5;border-radius:8px;overflow:hidden;\"\u003e\n\u003ch3 style=\"margin:0;padding:14px 16px;background:#f1f3f5;color:#1f2937;font-size:17px;font-weight:700;line-height:1.5;\"\u003e\u003cstrong\u003eQ: Does 48209-0660 include a ceiling assembly?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"margin:0;padding:14px 16px;color:#374151;font-size:15px;line-height:1.7;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The interior assembly and its controls must be selected separately for the RV’s system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;margin-bottom:18px;border:1px solid #d9dee5;border-radius:8px;overflow:hidden;\"\u003e\n\u003ch3 style=\"margin:0;padding:14px 16px;background:#f1f3f5;color:#1f2937;font-size:17px;font-weight:700;line-height:1.5;\"\u003e\u003cstrong\u003eQ: Is it a heat pump?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"margin:0;padding:14px 16px;color:#374151;font-size:15px;line-height:1.7;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. It is a cooling air conditioner. Optional electric resistance heat, where approved, is a separate accessory.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;margin-bottom:18px;border:1px solid #d9dee5;border-radius:8px;overflow:hidden;\"\u003e\n\u003ch3 style=\"margin:0;padding:14px 16px;background:#f1f3f5;color:#1f2937;font-size:17px;font-weight:700;line-height:1.5;\"\u003e\u003cstrong\u003eQ: What does the 8.9 A figure mean?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"margin:0;padding:14px 16px;color:#374151;font-size:15px;line-height:1.7;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It is the listed compressor draw, not the whole unit’s current. Fan load, starting demand and other RV appliances must also be considered.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;margin-bottom:18px;border:1px solid #d9dee5;border-radius:8px;overflow:hidden;\"\u003e\n\u003ch3 style=\"margin:0;padding:14px 16px;background:#f1f3f5;color:#1f2937;font-size:17px;font-weight:700;line-height:1.5;\"\u003e\u003cstrong\u003eQ: Is this an evaporative cooler?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"margin:0;padding:14px 16px;color:#374151;font-size:15px;line-height:1.7;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Mach 15 uses a refrigerant cooling system. The earlier evaporative-cooling label was incorrect.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;margin-bottom:18px;border:1px solid #d9dee5;border-radius:8px;overflow:hidden;\"\u003e\n\u003ch3 style=\"margin:0;padding:14px 16px;background:#f1f3f5;color:#1f2937;font-size:17px;font-weight:700;line-height:1.5;\"\u003e\u003cstrong\u003eQ: Will a 14-inch roof opening guarantee a fit?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"margin:0;padding:14px 16px;color:#374151;font-size:15px;line-height:1.7;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Roof support, thickness, mounting angle, shroud clearance, ceiling configuration, wiring and controls must also match.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;margin-bottom:18px;border:1px solid #d9dee5;border-radius:8px;overflow:hidden;\"\u003e\n\u003ch3 style=\"margin:0;padding:14px 16px;background:#f1f3f5;color:#1f2937;font-size:17px;font-weight:700;line-height:1.5;\"\u003e\u003cstrong\u003eQ: Can I substitute the newer 38209 part automatically?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"margin:0;padding:14px 16px;color:#374151;font-size:15px;line-height:1.7;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Do not assume that every later part number or production revision is identical. Confirm the complete replacement match, ceiling controls and actual unit rating plate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;margin-bottom:18px;border:1px solid #d9dee5;border-radius:8px;overflow:hidden;\"\u003e\n\u003ch3 style=\"margin:0;padding:14px 16px;background:#f1f3f5;color:#1f2937;font-size:17px;font-weight:700;line-height:1.5;\"\u003e\u003cstrong\u003eQ: What should be checked for a non-ducted installation?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"margin:0;padding:14px 16px;color:#374151;font-size:15px;line-height:1.7;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The exact available listing identifies 48209-0660 as Ducted Quiet. A non-ducted conversion needs an approved ceiling\/control arrangement; it is not represented here as a universal drop-in fit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdetails open=\"open\" style=\"margin-top:24px;\"\u003e\u003csummary style=\"font-weight:700;color:#b52828;cursor:pointer;\"\u003eMore product details \u0026amp; helpful resources\u003c\/summary\u003e\u003cdiv style=\"padding-top:16px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer references:\u003c\/strong\u003e \u003ca href=\"https:\/\/coleman-mach.com\/service-support\/find-model-number\/\"\u003eWhere to locate rooftop and ceiling model numbers\u003c\/a\u003e. The \u003ca href=\"https:\/\/manuals.plus\/m\/8cc8c38a597cf1d4959fc60030c983f10e75ff38e9cb6156e003b85b0a063761\"\u003emanufacturer’s legacy Mach 15 PS family data sheet\u003c\/a\u003e is family-level technical background; use the exact unit plate for variant-specific electrical requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e The existing exact-part listing specifies a limited two-year warranty, subject to the applicable Coleman-Mach terms, exclusions and installation\/use requirements.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eSelect this legacy MPN by the complete rooftop and ceiling system information. PowerSaver design does not guarantee freedom from breaker trips or a fixed interior temperature; ambient conditions and the RV’s heat gain affect cooling demand.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"COLEMAN RVP","offers":[{"title":"Default Title","offer_id":47651397107997,"sku":"BXPQ_48209-0660","price":1604.9,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0689\/2771\/7661\/files\/ImageServer_8908f362-1e69-472d-98b1-65c46336d183.jpg?v=1757601176","url":"https:\/\/www.mytruckpoint.ca\/products\/coleman-mach-48209-0660-mach-15-powersaver-air-conditioner","provider":"TruckPoint","version":"1.0","type":"link"}